ELTECH has been developing vibration sensors, crack sensors, tilt sensors and temperature/humidity sensors.
Although wireless communication based on KR920 LoRa is supported fundamentally, depending on the customer’s request, NB-IOT, ZigBee and WIFI communications can be supported.
Onboard antenna and external antenna wireless communications are supported.
They support
AES-128 encryption.
They convert raw data into a format suitable for wireless communication environment before transfer.
They are
EX ia IIC T4 rated.
They are
IP67 waterproof rated.
size (H x W x D) | 100 x 79 x 49mm |
---|---|
weight | 200g |
IP-code | IP54 |
operating voltage | 3.0V to 3.6V |
operating temperature | -20°C to +85°C |
measurement range | Up to 50mm |
resolution | 0.1mm |
communication | Analog (include data ready and threshold interrupt) |
---|---|
frequency | 816~920MHz |
size (H x W x D) | 100 x 79 x 49mm |
---|---|
weight | 200g |
IP-code | IP54 |
operating voltage | 3.0V to 3.6V |
operating temperature | -20°C to +85°C |
measurement Axis | 3 Axis (X, Y, Z) |
measurement range | Up to ±10° for each Axis |
resolution | 0.01° |
communication | SPI (include data ready and threshold interrupt) |
---|---|
frequency | 816~920MHz |
size (H x W x D) | 100 x 79 x 49mm |
---|---|
weight | 200g |
IP-code | IP54 |
operating voltage | 3.0V to 3.6V |
operating temperature | -20°C to +85°C |
measurement range | Up to 1kHz for each Axis |
resolution | 0.2mg |
communication | I2C/SPI (include data ready and threshold interrupt) |
---|---|
frequency | 816~920MHz |
size (H x W x D) | 100 x 79 x 49mm | |
---|---|---|
weight | 200g | |
IP-code | IP54 | |
operating voltage | 3.0V to 3.6V | |
operating temperature | -20°C to +85°C | |
Humidity | measurement range | 0 ~ 100% relative humidity |
accuracy | ±2% | |
response time | 8sec | |
Temperature | measurement range | -20°C to +85°C |
accuracy | ±0.3°C | |
response time | < 30sec |
communication | I2C (include data ready and threshold interrupt) |
---|---|
frequency | 816~920MHz |
operating temperature | -10°C to +50°C |
---|---|
operating pressure | 700 to 1300mbar |
operating Humidity | 5% to 95% Rh (Non-condensing) |
sensor type | Galvanic cell (lead-oxygen battery) |
measurement range | 0~25% volume Oxygen |
accuracy | < ±1.0% full scale |
response time(T90) | < 15sec for 90% response |
zero offset voltage | Less than 0.5mV in 100% N2 @ 25℃ 40% RH |
operating temperature | -10°C to +50°C |
---|---|
operating pressure | 800 to 1200mbar |
operating Humidity | 15% to 90% Rh (Non-condensing) |
sensor type | Electrochemical |
measurement range | 0~20ppm |
resolution | < 0.1ppm typical |
response time(T90) | < 30sec |
repeatability | < ±5% |
operating temperature | -20°C to +50°C |
---|---|
operating pressure | 800 to 1200mbar |
operating Humidity | 0% to 90% Rh (Non-condensing) |
sensor type | Electrochemical |
measurement range | 0 ~ 500ppm |
resolution | < 0.1ppm typical |
response time(T90) | < 30sec |
repeatability | < ±2% |
operating temperature | -20°C to +55°C |
---|---|
output sensitivity | 29±5mV / % methane |
linear to | 3% methane |
Long Term Sensitivity Drift | < 5% signal / month |
measurement range | 0 ~ 100 % LEL |
response time(T90) | < 10sec |
operating temperature | -20°C to +50°C |
---|---|
operating Humidity | 0% to 90% Rh (Non-condensing) |
sensor type | NDIR |
measurement range | 0 ~ 500ppm |
resolution | 10ppm typical |
response time(T90) | < 30sec |
repeatability | < ±2% |
operating temperature | -30°C to +50°C |
---|---|
operating pressure | 800 to 1200mbar |
operating Humidity | 15% to 90% Rh (Non-condensing) |
sensor type | Electrochemical |
measurement range | 0 ~ 20ppm |
resolution | 0.1ppm typical |
response time(T90) | < 40sec |